tenant.l2out.external_epg.subnet

A subnet defines the IP address range that can be used within the bridge domain. While a context defines a unique layer 3 space, that space can consist of multiple subnets. These subnets are defined per bridge domain.

ACI class

fvSubnet

RN

subnet-[{subnet}]

Cursor

L2outExternalEpgSubnetCursor

Parent

tenant.l2out.external_epg

Atomic

Attributes

Accepted as keyword arguments of .subnet(subnet) and of .set(**attrs) on this cursor. Enum parameters also accept the plain string.

parameter

wire

type

values

default

description

subnet (positional)

ip

str

The IP address and mask of the default gateway.

subnet_control

ctrl

FvSubnetControl

unspecified, querier, nd, no-default-gateway

nd

The subnet control state. The control can be specific protocols applied to the subnet such as IGMP Snooping.

description

descr

str

Specifies the description of a policy component.

ip_dp_learning

ipDPLearning

FvipDPLearning

disabled, enabled

enabled

Knob to disable IP Dataplane Learning for Host(/32, /128) and for BD Subnet

name

name

str

preferred

preferred

bool

False

Indicates if the subnet is preferred (primary) over the available alternatives. Only one preferred subnet is allowed.

scope

scope

FvRouteScp

public, private, shared

private

The network visibility of the subnet.

virtual

virtual

bool

False

Treated as virtual IP address. Used in case of BD extended to multiple sites.

Children

maker

creates

position

.anycast_endpoint(mac, **attrs)

fvEpAnycast

tenant.l2out.external_epg.subnet.anycast_endpoint

.nlb_endpoint(**attrs)

fvEpNlb

tenant.l2out.external_epg.subnet.nlb_endpoint

.endpoint_network_config(name, **attrs)

fvCepNetCfgPol

tenant.l2out.external_epg.subnet.endpoint_network_config

Bind aliases

Lazy references, resolved closed-world at push time.

alias

target

flavor

relation

l3out=

l3extOut

name

fvRsBDSubnetToOut

nd_ra_prefix_policy=

ndPfxPol

name

fvRsNdPfxPol

APIC diagnostics

States the APIC can flag on this class — it accepts the configuration and reports the inconsistency afterwards.

Config issues

code

meaning

multiple-tag-selector-match

Tag(s) matching more than one ESG TagSelector. Subnets can only be associated to a single ESG TagSelector via Tags.

multiple-tag-selector-match-after-single-match

Tag(s) are now matching more than one ESG TagSelector. The original match is still active. Subnets can only be associated to a single ESG TagSelector via Tags.

Faults

code

condition

F4125